2-138 A 50-cm-long, 0.2-cm-diameter electric resistance wire submerged in water is used to determine the boiling heat transfer coefficient in water at 1 atm experimentally. The surface temperature of the wire is measured to be 130°C when a wattmeter indicates the electric power consumption to be 4.1 kW. Then the heat transfer coefficient is
a) 43,500 W/m2 · °C
b) 137 W/m2 · °C
c) 68,330 W/m2 · °C
d) 10,038 W/m2 · °C
e) 37,540 W/m2 · °C
 
 
View Solution
 
 
 